home *** CD-ROM | disk | FTP | other *** search
/ The World of Computer Software / The World of Computer Software.iso / kwstat33.zip / LATENEWS.DOC < prev    next >
Text File  |  1993-01-04  |  7KB  |  145 lines

  1. KWIKSTAT 3.3 LATENEWS, Release 3
  2.  
  3. Corrections to manual:
  4.  
  5. p 1-13,14: The figure 1.7 should show a pick (menu) list of field names.
  6. Use up and down arrow keys to highlight field/variable to choose, then
  7. press Enter, or point to the field name with the mouse pointer
  8. and click once. Throughout the manual, when you choose one field for
  9. an analysis, a pick list is used rather than typing in the number
  10. of the field name. (see note 2 below)
  11.                   
  12. p. 4-26: The table should be:
  13.  
  14. Gp1     Gp2     Gp3     Gp4
  15. 60.8    78.7    92.6    86.9
  16. 67.0    77.7    84.1    82.2
  17. 54.6    76.3    90.5    83.7
  18. 61.7    79.8            90.3
  19.  
  20. The formula on page 4-43 should read:
  21.  
  22. U = n1n2 - [n1(n1+1)]/2 - S
  23.  
  24. The only difference is that the 90.3 is in Gp4 instead of Gp3.
  25.  
  26. 1. Loading KWIKSTAT in a subdirectory that had a previous version of 
  27. KWIKSTAT will not overwrite any of your DBF files. To save space on disk, 
  28. erase old Kwikstat programs prior to ver 3. (ERASE *.EXE), or load 
  29. Kwikstat in a different directory (e.g., \KS33).
  30.  
  31. 2. Some actual screens may differ from the ones in the manual, since some do 
  32. not reflect changes made for mouse support. An important difference is
  33. when you are asked to choose a field for analysis. In the manual, and
  34. in some of the examples, you are told to press 2, for example, to choose
  35. the second field name. Now, in many instances, fields appear in a menu-like
  36. list. In this case, instead of pressing 2, you use the up and down arrow
  37. keys to highlight your choice, then press Enter, or use the mouse pointer 
  38. to choose the field by name.
  39.  
  40. 3. In several analyses, a late change has been made to give you more support 
  41. in viewing and printing the results of an analysis. In most cases, you will 
  42. be asked if you want to view/print results. If you answer Yes, a viewer will 
  43. be used to display the results of an analysis. Using the button bar commands
  44. at the bottom of the screen, you can press function keys or click with a 
  45. mouse to output the report (to a file or printer), add a title to the report, 
  46. set the left margin, choose a printer code, or exit from the viewer.
  47.  
  48. If you save the contents of the viewer to a file, you can merge the 
  49. information into your word processor, or view/print the information 
  50. at a later time. To use the viewer from the DOS prompt, enter TXVIEW and
  51. the name of the file to view. The viewer works on all ASCII text files.
  52. For example, if you want to view a file named REPORT.TXT, you would enter 
  53. the command
  54.  
  55.         TXVIEW REPORT.TXT
  56.  
  57. 4. Hercules graphics are supported on all modules except Simulations. Use a
  58. Hercules/CGA Simulator such as SIMCGA or HGCIBM (both shareware programs) 
  59. to allow you to run the simulations module on a Hercules monitor. If you 
  60. use a simulator, specify a CGA monitor in the setup routine. Printing
  61. graphics screens in the simulations module is not supported.
  62.  
  63. 5. When displaying some graphs in EGA or VGA mode, you can change colors
  64. using the following keys
  65.  
  66. F1, F2, F3 - change display colors
  67. F5 - go to black and white
  68. F6 - white on black
  69. F8,F9,F10 - change background in VGA mode (gradual changes)
  70.  
  71. 6. Version 3.3 supports display and printing of graphs in EGA and VGA modes
  72. on Epson and HP Laserjet compatible printers. This allows much nicer results 
  73. in the printout of graphs. Not all combinations of printers and monitors are 
  74. supported when printing graphs. If you have problems printing graphics, try 
  75. another selection in the setup routine (Helps menu) For example, if you are 
  76. unable to print using the high resolution Epson or Laserjet options, try the 
  77. low resolution options. The high resolution options ONLY work for EGA and VGA 
  78. monitors and high-res Epson or Laserjet printers. 
  79.  
  80. 7. You can capture an EGA or VGA graphic screen into a PCX file. Display a 
  81. captured PCX graph by using the command SHOW from the DOS prompt. For 
  82. example, if you capture the file named GRAPH.PCX, enter 
  83.  
  84.         SHOW GRAPH.PCX EGA
  85.  
  86. if captured in EGA mode. Use VGA in the command if captured in VGA mode. 
  87. Captured graphs can be imported into programs such as word processors,
  88. slideshow programs, publishing programs, etc. that support the PCX
  89. standard. When you import into WordPerect, you usually need to choose
  90. to change the graph to black and white, invert the colors and scale
  91. the graph to get the best detail.
  92.  
  93. 8. Because it caused so many questions, a plot now usually does not ask 
  94. you what monitor type to use -- it uses only the one you specified in 
  95. the setup. This (hopefully) means that the program will be able to 
  96. handle printing graphs more consistently. If you miss this feature, you
  97. can bring it back by copying the file SHOW.BAT to MCHOICE.INI (i.e.
  98. COPY SHOW.BAT MCHOICE.INI). If you want a plot displayed in a different
  99. monitor type, or if you like the way it prints using a different monitor
  100. type (some people like the CGA/Laserjet printout better than the 
  101. VGA/Laserjet printout), you can choose a different monitor/printer by
  102. choosing the Setup option from the Helps menu or by running the KSETUP
  103. program from the DOS prompt.
  104.  
  105. 9. In crosstabulations, you are given the option to choose what numbers
  106. will appear in the table - Expected values, Contribution to Chi-Square
  107. and Row/Col/Total Percents. The new entry not descibed in the manual is
  108. called CONTRIB. This number is the "contribution to Chi-Square". That
  109. is, the number shows how much a particular cell contributed to the
  110. size of the Chi-Square statistic. This often comes in handy when you
  111. are trying to discover what may have caused a table to result in a
  112. low p-value (a high Chi-Square statistic).
  113.  
  114. 10. Copy/Backup option in Data menu - this option allows you to copy a
  115. database to a new filename or destination or to make a backup copy of 
  116. your database. If you are going to be doing manipulation of a database, 
  117. it is a good idea to make a backup first, in case a problem occurs that 
  118. effects data in your original database. 
  119.  
  120. 11. Multiple regression now allows 20 variables. However, if you push the
  121. program to the limit with many variables and hundreds of records, you may 
  122. run into an out-of-memory problem.
  123.  
  124. 12. The maximum length of a path for Kwikstat is 30 characters.
  125.  
  126. 13. Beginning with release 3, there are two additional functions available 
  127. in the database. AVE(list) and SD(list), which calculates an average of the 
  128. listed fields and SD calculates the standard deviation. For example, If you 
  129. have fields named REP1, REP1 and REP3, doing a Field Replace with 
  130. =AVE(REP1,REP2,REP3) will place the average in the field. Doing a Field 
  131. replace with =STD(REP1,REP2,REP3) will place the standard deviation of the
  132. tree numbers in the field. Add the Math Calculator functions to the table 
  133. on page 2-51. 
  134.  
  135. 14. To support network use, Release 3 causes all temporary files to be 
  136. stored on the defined default path (you specified in setup). This means 
  137. that if you are running Kwikstat on a network, using your local machine as 
  138. the default Kwikstat path, all temporary files used by Kwikstat will be 
  139. stored on your local disk. This prevents problems caused by more than two 
  140. people trying to access the same temporary file at the same time. 
  141.  
  142. 15. When you choose edit from the Data menu, it goes directory to record 1 
  143. for editing. Use the Goto (F5) to move to a specific record once you are in 
  144. editing mode. 
  145.